Up to 1400 plate capacity. Two airlocks and two temperature zones.

Up to 1400 plate capacity. Two airlocks and two temperature zones.

Options and Specs Images and Video
 

The Whitley A55 Anaerobic Workstation is the latest innovation in workstation technology from Don Whitley Scientific. Complete with two built-in, rapid airlocks and intuitive touch-screen control panel, this new workstation allows you to work completely glove AND sleeve-free.

No gloves, no sleeves, no waiting. The A55 is the first four port workstation to be offered with our new glove/sleeve-free entry system. This porthole design is ideal for users who are in and out of the chamber for short periods of time and use the workstation mainly as an anaerobic incubator. We recommend our conventional, sleeve-gassing ports for users who will be spending extended periods of time working inside the chambers. Now you can choose the entry system best suited for your workflow. The A55 offers any combination of sleeved or rapid-entry ports.

A55 Front Options

The work and storage areas of the atmosphere chamber are temperature controlled with an impressively low gradient threshold. This allows the full internal volume to be used as an incubator if desired. The A55 anaerobic chamber also offers the option of split incubation temperatures with separation between the two sides. The dual airlocks are flushed with nitrogen as an additional cost savings.

From a relatively small footprint we have been able to maximize incubating capacity to create the perfect environment, whether for a few plates or hundreds of plates. To introduce samples or equipment, the built-in, dual 12 liter rapid-cycle airlocks have the capacity to move up to 40 Petri dishes per airlock into the workstation in 60 seconds. There is also the option to specify the 15cm letterbox for rapid sample entry. As with our other Whitley Workstations, the A55 anaerobic cabinet also incorporates patented use of Anotox (activated carbon impregnated with ferric hydroxide) for atmospheric conditioning. By using Anotox, the catalyst does not have to be removed and regenerated routinely. Anotox removes the hydrogen sulfide and volatile fatty acids (by-products of anaerobe metabolism) that poison the catalyst and impede the growth of anaerobes.

Download Brochure

Features:

No gloves, no sleeves - complete bare-handed working
Automated humidity control with no user maintenance
Two rapid, built-in airlocks with mechanical and electrical interlocks - no risk of compromising conditions inside the chamber
Touch-screen interface with password protected user levels
Dual gas operation and automatic commissioning cycle
Constructed from 10mm thick annealed acrylic, most robust chambers available
Tangential fans create laminar flow in chamber, internal atmosphere is constantly being circulated over catalyst, Anotox, and heating mat for a consistent and strictly anaerobic environment
Double internal power socket, 2 Amp max
800 plate capacity with ample work space, four porthole doors
Gas requirements: 1 x ANO2 = 10% H2, 10% CO2, 80% N2 -OR- 1 x ANO2 and Nitrogen
No requirement to bake catalyst, simply replace catalyst and Anotox annually
The Whitley A55 is available with custom port options. All four ports can be rapid entry, conventional sleeved ports or users can choose a combination of rapid entry ports and conventional sleeved ports.
Removable Front for thorough cleaning and sanitizing; enables users to introduce or remove equipment or bulk quantities of samples quickly
 

Options:

Anaerobic Conditions
Monitoring System
This factory-fitted option monitors and displays real time oxygen levels within the workstation. Depending on the percentage of oxygen present, the chamber/airlock symbol on the touch screen will read green, yellow or red. The electronic Anaerobic Conditions Monitoring System is complete with oxygen sensor and a special software package. The oxygen sensor is located inside the chamber for accurate, real-time readings. The sensor is easily and quickly calibrated via the touch screen.
See Details

Trolley
Our custom-designed trolley frees up bench space and allows the chamber to be moved. The trolleys are built with high quality tubular steel and smooth rolling lockable wheels. They offer a sturdy and stable frame to support your use of our anaerobic and microaerophilic workstations.
See Details

Gas Pressure Monitor
Designed as a method of monitoring the gas supply. The system will indicate the status of both sides of the switchover: FULL – IN SERVICE, and DEPLETED. When a cylinder or cylinder bank is depleted, the green light will change to a red light, and the audible alarm will sound.
See Details

15cm Letterbox
Ideal for quickly introducing small quanitites of samples and supplies

Spare Cable Gland
Used to accommodate a power or data cable without affecting the chamber conditions

Data Logging
Access temperature, humidity, chamber pressure and anaerobic conditions. Stores up to 30 days of system information, accessed via USB port.

Internal Storage Trays
Maximum 2 per unit; positioned under the shelf

10 Plate Dish Rack
Easily stack and move 10 petri dishes. Prevents spills with a rigid design

Dual incubation
temperatures
each side of the A55 can be set at different temperatures with separation in between the two sides.

Specs:

Capacity (Liters) 650
Capacity (Petri Dishes) 800 - 1400
Port/Airlock Capacity 40 x 90mm Petri dishes
Airlock Size 2 x 12 liters
Refrigeration Not available
Airlock Cycle Time 60 seconds
Automatic Dehumidifier Fitted as standard
Removable Front Fitted as standard
Dimensions (w/d/h - mm) 2150 x 720 x 710
Weight (lbs/kg) 463 / 210
Temperature Range (°C) 10°C above ambient up to 45°C
Temperature Zones 2
Simultaneous Users 2

Image Gallery

A55 Gallery
Click image to enlarge
 

Featured Videos

Dr Andrew Dempster, Centre for Biomolecular Sciences, University of Nottingham_Testimonial Video

Dr Andrew Dempster Testimonial

Dr Jane Freeman from Leeds General Infirmary

Dr Jane Freeman Testimonial

Whitley Anaerobic Workstations

Whitley Anaerobic Workstations

Anaerobic Conditions Monitor Animation

Anaerobic Conditions Monitor Animation

Microbiology Research at the School of Dentistry, University of Leeds

Microbiology Research at the School of Dentistry, University of Leeds

Why Choose Whitley?

Why Choose Whitley?


Motorized Trolley

Whitley Workstation - Airlock Operation

Whitley Workstation - Airlock Operation

Whitley Workstation - Sleeve Assembly

Whitley Workstation - Sleeve Assembly

Whitley Workstation - Sleeved Port Operation

Whitley Workstation - Sleeved Port Operation

Whitley Workstation - Removable Front

Whitley Workstation - Removable Front

Whitley Workstation - O2 Cell Calibration

Whitley Workstation - O2 Cell Calibration