Massive 30 liter airlock (our largest available) and up to 610 plate capacity.

Massive 30 liter airlock (our largest available) and up to 610 plate capacity.

Options and Specs Images and Video
 

The Whitley Workstation A85 has a 610 plate capacity and is constructed of rigid acrylic (6mm thick front panels, 10mm thick side panels). The panels are chloroform annealed, creating a uni-body construction capable of withstanding positive pressure well in excess of the 4 PSI maintained constantly by the system.

Patented use of “oval” shaped gloveless entry ports allow the introduction of samples/materials by acting as a transfer airlock. This process allows the user to place their materials in the chamber while placing their hands in the chamber, reducing overall gas consumption considerably by not having to run a secondary airlock cycle. Evacuation and gassing of sleeves as well as opening of inner doors are controlled via the wireless footswitch. The system uses a radio controlled footswitch to eliminate clumsy wiring. There is a manual override for use when necessary.

Patented use of Anotox (activated carbon impregnated with ferric hydroxide) for atmospheric conditioning. By using Anotox, the catalyst does not have to be removed and baked routinely. Anotox removes the Hydrogen Sulfide and volatile fatty acids (by-products of anaerobe metabolism) that poison the catalyst and can impede the growth of anaerobes.

The entire workstation is temperature controlled, allowing for temperatures between 4°C and 44°C. There is no need for extra incubators and loss of space efficiency. Humidity is controlled automatically by an electronically controlled water removal system. Water is pumped to a container containing a silver-impregnated bacteriostatic wick to evaporate the water externally. There are no containers to empty. The humidity setting is user programmable.

The electronics and lighting are located in an external control housing. There is no need to compromise the workstation to change light bulbs or perform fuse replacement.

The 100 plate airlock is an option to the Whitley Workstation A85. The airlock cycle is electronically controlled and requires only a press of a button to operate. Catalyst dedicated to the airlock is housed internally and does not need to be changed or replaced.

Download Brochure
Anaerobic Workstation with Refrigeration

Features:

Large 30 litre airlock with powered internal door provides effective sample and equipment transfer in the fastest possible time whilst ensuring the minimum amount of oxygen is introduced into the chamber.
Manual, oval glove ports enable you to work gloved or bare handed. Each gloveport also acts as a mini-airlock so you can transfer up to 10 plates through each as you insert your arms.
Color, touch-screen control panel for ease of use and for visual display of parameters such as temperature, humidity, and airlock cycle status. Features password protected user levels
Optional refrigeration unit available should you need to store samples prior to incubation.
Dual gas operation and automatic commissioning cycle
Constructed from 10mm thick annealed acrylic, most robust chambers available
Tangential fans create laminar flow in chamber, internal atmosphere is constantly being circulated over catalyst, Anotox, and heating mat for a consistent and strictly anaerobic environment
Double internal power socket available, 2 Amp max
Customized trolley hardware available, makes moving the workstation easy and fast.
Accommodates over 540 plates with ample work space, two porthole doors
Gas requirements: 1 x ANO2 = 10% H2, 10% CO2, 80% N2 -OR- 1 x ANO2 and Nitrogen
No requirement to bake catalyst, simply replace catalyst and Anotox annually
 

Options:

Anaerobic Conditions
Monitoring System
This factory-fitted option monitors and displays real time oxygen levels within the workstation. Depending on the percentage of oxygen present, the chamber/airlock symbol on the touch screen will read green, yellow or red. The electronic Anaerobic Conditions Monitoring System is complete with oxygen sensor and a special software package. The oxygen sensor is located inside the chamber for accurate, real-time readings. The sensor is easily and quickly calibrated via the touch screen.

See Details


Trolley
Our custom-designed trolley frees up bench space and allows the chamber to be moved. The trolleys are built with high quality tubular steel and smooth rolling lockable wheels. They offer a sturdy and stable frame to support your use of our anaerobic and microaerophilic workstations.
See Details

Gas Pressure Monitor
Designed as a method of monitoring the gas supply. The system will indicate the status of both sides of the switchover: FULL – IN SERVICE, and DEPLETED. When a cylinder or cylinder bank is depleted, the green light will change to a red light, and the audible alarm will sound.
See Details

15cm Letterbox
Ideal for quickly introducing small quanitites of samples and supplies

Spare Cable Gland
Used to accommodate a power or data cable without affecting the chamber conditions

Data Logging
Access temperature, humidity, chamber pressure and anaerobic conditions. Stores up to 30 days of system information, accessed via USB port.

Internal Storage Trays
Maximum 2 per unit; positioned under the shelf

10 Plate Dish Rack
Easily stack and move 10 petri dishes. Prevents spills with a rigid design

Specs:

Capacity (Liters) 300
Capacity (Petri Dishes) 540 - 610
Port/Airlock Capacity 90 x 90mm Petri dishes
Airlock Size 30 liters
Refrigeration Option Available
Airlock Cycle Time 300 seconds
Automatic Dehumidifier Fitted as standard
Removable Front Not Available
Dimensions (w/d/h - mm) 1570 x 840 x 760
Weight (lbs/kg) 330 / 150
Temperature Range (°C) 10°C above ambient up to 45°C
Trolley Recommended
Images and Video

Image Gallery

A85 Gallery
Click image to enlarge
 

Featured Videos

Dr Andrew Dempster, Centre for Biomolecular Sciences, University of Nottingham_Testimonial Video

Dr Andrew Dempster Testimonial

Dr Jane Freeman from Leeds General Infirmary

Dr Jane Freeman Testimonial

Whitley Anaerobic Workstations

Whitley Anaerobic Workstations

Anaerobic Conditions Monitor Animation

Anaerobic Conditions Monitor Animation

Microbiology Research at the School of Dentistry, University of Leeds

Microbiology Research at the School of Dentistry, University of Leeds

Why Choose Whitley?

Why Choose Whitley?


Motorized Trolley

Whitley Workstation - Airlock Operation

Whitley Workstation - Airlock Operation

Whitley Workstation - Sleeve Assembly

Whitley Workstation - Sleeve Assembly

Whitley Workstation - Sleeved Port Operation

Whitley Workstation - Sleeved Port Operation

Whitley Workstation - Removable Front

Whitley Workstation - Removable Front

Whitley Workstation - O2 Cell Calibration

Whitley Workstation - O2 Cell Calibration