Table Top Autoclave
Type D-45 D-65 D-90 D-100 D-150 D-200
Chamber Dimensions in mm.
(diameter x depth)
344 x 500 400 x 500 400 x 700 500 x 500 500 x 750 500 x 1000
External Dimensions in mm.
Width 618 750 750 850 850 850
Height 550 630 630 730 730 730
Depth 740 770 970 810 1050 1300
Weight (lbs/kg) 231/105 275/125 319/145 363/165 418/190 462/210
Chamber Volume in Liters 45 65 90 100 150 200
D Series Brochure Larger Autoclaves

Loading Capacity

  • Erlenmeyer Flasks
  • Schott-Duran Flasks
Systec D-45 D-65 D-90 D-100 D-150 D-200
250 ml 24 23 31 2 x 30 2 x 42 2 x 59
500 ml 12 15 21 2 x 15 2 x 24 2 x 40
1000 ml 8 9 13 12 18 23
2000 ml 3 6 8 7 9 14
3000 ml - 3 4 6 8 11
5000 ml - - - 3 5 7
Systec D-45 D-65 D-90 D-100 D-150 D-200
250 ml 24 31 40 2 x 36 2 x 54 2 x 83
500 ml 18 23 31 2 x 26 2 x 40 2 x 59
1000 ml 10 15 18 18 26 40
2000 ml 5 8 10 12 14 23
5000 ml - 3 4 6 8 11
10000 ml - - - 3 5 7

 

Innovative automatic safety door lock

Easy and safe. When the autoclave lid is closed, the lid is automatically locked by a circumferential ring system. A special lip seal made of heat resistant silicone provides reliable sealing. As steam pressure builds within the sterilizer, the seal becomes tighter.

The lid also opens easily – either at the push of a button or automatically at the end of a sterilization cycle.

The door-locking system on this benchtop autoclave, is temperature dependent and adheres to national and international safety standards. The door remains locked as long as there is excess pressure in the chamber. The lid, like other parts of the pressure vessel and housing, is made of stainless steel. The modern design faceplate, which also contains the control panel, display and part of the control technology, is made of heat resistant and insulated plastic. There is no risk of the autoclave operator coming into contact with hot components.

autoclave lock
 

autoclave steam

Steam generation

A steam generator is incorporated in the sterilizer housing providing substantial benefits:

  • No heating elements and no reservoir for dirty water in the chamber
  • With stand-by pre-heating option, only 10 min. heating time to 121° C with an empty chamber
  • Improved removal of air from the empty chamber via pulsed heating (rapid attainment of optimal steam atmosphere, even without a vacuum)
  • Accuracy better than ± 0.5 C with empty chamber
  • Quicker cooling as neither the hot water in the chamber nor the separate steam generator need to be cooled
  • After cooling, steam is immediately available for the next sterilization run.
 

Pressure-safe up to 5 bar/150 °C

The Systec D-Series benchtop autoclave units are the first of its kind to be designed for higher pressures and temperatures. The standard pressure sterilizer chamber is designed for 5 bar/150 °C. If the expanded pressure and temperature model is selected as an option, all control and safety components are adapted to the higher temperature and pressure. This option may be retrofitted to existing D- series benchtop autoclave units.

Systec D-Series benchtop autoclaves are equipped direct from the factory for sterilization temperatures up to 140 °C and 4 bar of pressure.

autoclave chamber
 

autoclave quality

Quality materials quality manufacturing

The pressure vessel is made of corrosion-resistant electro-polished stainless steel 1.4571 (V4A) AISI 316 Ti and therefore very easy to clean. The benchtop autoclave framework and housing are also made of stainless steel. The highly efficient, high-quality Hanno-Tect insulation material releases no particles and therefore the Systec D-Series sterilizer is ideal for use in clean room environments

Exhaust steam is condensed automatically via a PT 100-regulated cooling system. This prevents odors and protects waste water piping.

 

Controls – new generation

The Systec D-Series benchtop autoclave units have “comprehensive intelligence”: Pressure is controlled via an electronic pressure transducer. Additionally, there is a flexible temperature sensor in the sterilization chamber or in a reference vessel (for liquids) and another sensor at the coldest part of the chamber, the condensate outlet. The microprocessor, specially developed for our laboratory autoclave, controls all relevant functions such as steam pressure, temperature and sterilization time as well as optional rapid cooling, pre / post-vacuum and drying.

Menu-presented instructions in easy to read text form. Membrane keyboard with acoustic confirmation signal. Ergonomically located in a logical and easy to operate position.

autoclave controls

Benchtop Autoclave Gallery

Autoclave Videos


Autoclave Videos

Cooling options to fit your laboratory needs.

  • Level 1 Cooling
  • Level 2 Cooling
  • Level 3 Cooling

Cooling Coils

Cooling coils with support pressure provide a coil wrapped around the outside of the sterilization vessel. During the cooling phase, cool water circulates through the coils, reducing cool down time. Support pressure prevents liquids from boiling over during the cooling process, eliminating evaporative loss of sterilized liquids.

Cooling time 40mins
Autoclave Cooling Coils

Radial Ventilator

Radial ventilator for air circulation and accelerated heat removal from the sterilizer chamber. Combined with cooling coils and support pressure, the radial ventilator creates a more rapid exchange of heat from the chamber by utilizing an internal fan to circulate air.

Cooling time 20mins
Autoclave Radial Ventilator

UltraCool

UltraCool is an additional heat exchanger behind the radial ventilator. This special ridged coil provides a substantial increase in surface area for fast and efficient removal of heat during the cooling process. UltraCool can reduce cooling time by 90% compared to exhaust cooling and 50% compared to cooling coils with just the radial ventilator alone.

Cooling time 10mins
Autoclave Advanced Cooling

Options:


Click image to enlarge

IQOQPQ

The IQOQPQ process is based on a dynamic document that is tailored to meet the needs of each specific customer. The document is prepared by Microbiology International and approved by the customer prior to completing the task.

Read More


Click image to enlarge

Ticket Printer

Print program type, batch number, date, time, temperature, pressure and sterilization phase for total traceability


Click image to enlarge

Vacuum System

Required for Superdry option, but also allows for fractionated pre-vacuum. Useful for sterilization of waste bags, porous materials, hollow items and textiles.


Click image to enlarge

Superdry

Installed steam generator supplies heat to coils that surround sterilization vessel. Rapid surface drying occurs due to the heat and the sterilizer chamber being under a vacuum.


Click image to enlarge

Air Exhaust Filtration

The exhaust air is filtered via an autoclavable sterile filter. Neither aerosoles nor microorganisms can escape before the sterilization process is complete. Filter cartridge with PTFE membrane, pore size 0.2 um.


Click image to enlarge

Magnetic Stirrer

For stirring of liquids in large vessels during the sterilization process.

Accessories:


Click image to enlarge

Stainless Steel Baskets

Closed baskets used for waste sterilization, mesh baskets used for sterilizing liquids, open containers, and non-waste materials.


Click image to enlarge

EZ-Water System

The EZ-Water pRO is a tankless reverse osmosis system that offers on demand, high quality filtration with the most advanced technology on the market, including water quality and filter cartridge life monitoring, leak detection, automatic cleaning and a space-saving design. EZ-Water pRO was developed to pair with our line of autoclaves and MediaPrep systems to provide pure water for steam generation. The LED indicators provide real time feedback ensuring the correct water quality is being supplied to the system.


Click image to enlarge

Support Table

With shelf for support of benchtop autoclave capacity and storing items. The table framework is robust and stable and is made of cleanly welded stainless steel. Adjustment screws ensure stability on uneven floors.


Click image to enlarge

Transport and Loading Carraiges

Available for all benchtop autoclave models. Carraige tops can be set to seamlessly roll the loading tray into the autoclave. Saves time and hassle.


Air Compressor - Silent 50

Used for quick cooling if compressed air is not available


Condensate collection vessel

For units not connected to constant De-Ionized water supply